Serving North and South Carolina

Emergency service available

(864) 706-9511

Service

Private Utility Locating

The lines 811 will not mark are the ones that get hit.

Protect What's Below.

Carolina Hydrovac Inc. provides private utility locating to help identify underground lines that may not be marked through the public 811 system. Using electromagnetic locating equipment, ground-penetrating radar, and camera-and-sonde technology, we locate and mark detectable water, sewer, electrical, communication and other private utility lines.

The gap that 811 leaves is not small, and it is where most damage happens. The public system marks lines owned by the utility, up to the meter or the demarcation point. Everything past that — the site lighting, the irrigation, the feed to the pump house, the gas run to the generator, the sewer lateral, the fiber between two buildings on the same campus — belongs to the property owner, and no locator is coming out for it unless somebody hires one.

Everything past the meter belongs to the property owner, and nobody is coming out to mark it unless somebody hires them.

When greater certainty is needed, our locating services can be combined with hydro excavation to physically expose and verify a utility's position and depth before construction begins.

Options include:

  • Private utility locating
  • GPR scanning
  • Sewer camera and sonde locating
  • Utility mapping and GNSS data collection
  • Pre-excavation and pre-design investigations
  • Unknown and abandoned utility locating
  • Septic and sewer-line locating
  • Directional-drilling route clearance
  • Utility conflict investigation

The methods, and what each one is good for

  1. 01

    Electromagnetic locating

    A signal is applied to a conductive line and traced from the surface. Fast and accurate on metallic pipe and on anything with a tracer wire — and blind to plastic without one.

  2. 02

    Ground-penetrating radar

    Reads changes in the subsurface rather than a signal, so it can find non-conductive lines, voids and structures. Soil dependent: Upstate clay limits depth in a way sand does not.

  3. 03

    Camera and sonde

    A transmitter run inside a sewer or conduit, tracked from the surface. The way to locate a non-metallic line that has an accessible opening.

  4. 04

    Mapping and GNSS

    Located lines captured as coordinates rather than paint, so the information survives the next rain and can go on a drawing.

  5. 05

    Expose to confirm

    Where the answer has to be certain, hydro excavation puts the line in daylight and turns an estimate into a measurement.

Who needs it and when

Any dig past a meter

Commercial, industrial, campus and municipal property is full of private line, and an 811 ticket does not cover a foot of it.

Before design

Finding a conflict on a drawing costs a revision. Finding it during construction costs a change order.

Unknown and abandoned

Older sites carry line nobody has a record of. Some of it is dead, some is not, and the difference is worth establishing before a bucket does it.

Directional boring

A bore path crosses everything between entry and exit, out of sight. Clearing it beforehand is the whole safety case for the method.

Common questions

About private utility locating

We called 811. Why would we need a private locate?

Because 811 marks utility-owned lines, generally up to the meter or demarcation point, and nothing beyond it. Site lighting, irrigation, the feed to a pump house, gas to a generator, the sewer lateral, fiber between two buildings on one campus — all of it belongs to the property owner, and no public locator is coming out for any of it. On commercial, industrial and institutional ground that is most of what is in the way.

We already had GPR done. Do we still need to pothole?

It depends what the answer is worth. GPR is a surface reading and its accuracy varies with soil, depth and what else is nearby — in Upstate clay it returns less than it does in sand. If you need to know a line is roughly there, a locate is enough. If a bore path, a design conflict or a tie-in depends on the number, exposing the line is the only way to be certain of it.

Does ground-penetrating radar find everything?

No, and anyone who says otherwise is selling something. GPR reads changes in the subsurface, so it can find non-conductive pipe, voids and structures that an electromagnetic locator cannot — but its depth and clarity fall off in wet, conductive clay, which is what most of the Upstate is made of. It is one instrument among several, and where certainty is required the answer is to expose the line.

How accurate are locate markings?

Accurate enough to dig carefully near, not accurate enough to dig confidently on. Marks carry a horizontal tolerance and say nothing at all about depth. That gap — between "a line is near here" and "the line is at this depth and this offset" — is the whole reason potholing exists.

Can you tell whether a line is abandoned?

Locating equipment finds line; it does not reliably tell you whether that line is in service. On older industrial and redevelopment sites that distinction matters a great deal, and the dependable way to settle it is to expose the line and look at it.

Have a job that needs private utility locating?

Tell us where it is and what is in the way. Photographs and a site plan get you a far more accurate number.